Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 193
Filter
2.
Rev. bras. oftalmol ; 81: e0041, 2022. tab, graf
Article in English | LILACS | ID: biblio-1387975

ABSTRACT

ABSTRACT Glaucoma drainage devices are important therapeutic options for cases of refractory glaucoma, in which trabeculectomy with antimetabolites has shown high risk of failure. There are devices with different sizes, designs and materials, and several studies have been conducted to test their safety and effectiveness. Despite known complications, their use has progressively increased in recent years, and they are the primary surgical option, in some situations. The aim of this review is to discuss the importance, mechanisms, biomaterials, results and complications of glaucoma drainage devices.


RESUMO Os dispositivos de drenagem para glaucoma são importante opção terapêutica em casos de glaucomas refratários, nos quais a trabeculectomia com antimetabólitos tem alta chance de falência. Há dispositivos com diferentes tamanhos, desenhos e materiais, e muitos estudos foram realizados para testar sua segurança e eficácia. Apesar de suas conhecidas complicações, seu uso tem aumentado progressivamente nos últimos anos, inclusive como primeira opção cirúrgica, em algumas situações. O objetivo desta revisão foi discutir a importância, os mecanismos, os biomateriais, os resultados e as complicações dos dispositivos de drenagem para glaucoma.


Subject(s)
Humans , Glaucoma/surgery , Filtering Surgery/instrumentation , Glaucoma Drainage Implants , Biocompatible Materials , Glaucoma/physiopathology , Filtering Surgery/methods , Prosthesis Implantation , Intraocular Pressure/physiology
3.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Article in English | LILACS | ID: biblio-1376779

ABSTRACT

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/anatomy & histology , Cornea/physiology , Intraocular Pressure/physiology , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Elasticity/physiology , Models, Theoretical
5.
Rev. bras. oftalmol ; 81: e0049, 2022. tab, graf
Article in English | LILACS | ID: biblio-1387974

ABSTRACT

ABSTRACT Purpose To evaluate the cost-utility of the iStent inject® for the treatment of mild-to-moderate open-angle glaucoma (OAG) within the Brazilian Unified Health System (SUS). Methods A Markov model was developed, in which the effectiveness outcome measure was the incremental cost-effectiveness ratio (ICER: R$ / QALY quality-adjusted life-year). Direct medical costs were obtained from the SUS perspective. The base case comprised of a hypothetical cohort of patients with OAG using topical medication and being managed according to the Clinical Protocol and Therapeutic Guidelines (PCDT) and a real-world setting based on data from Datasus. The model's robustness through sensitivity analyses was tested. Results In the PCDT base case setting, the trabecular micro-bypass implant provided gains of 0.47 QALYs and an ICER of R$7,996.66/QALY compared to treatment with topical medication. In the real-world setting based on data from Datasus, the trabecular micro-bypass implant, provided gains of 0.47 QALYs and an ICER of R$4,485.68/QALY compared to treatment with topical medication. The results were robust to sensitivity analyses. Conclusion Incorporating iStent inject® to SUS provides an improvement in the patient's quality of life with an additional cost that warrants the benefit provided to patients. Results may be considered cost-effective compared to topical medication.


RESUMO Objetivo Avaliar a relação custo-utilidade do iStent inject® para o tratamento do glaucoma de ângulo aberto leve a moderado no Sistema Único de Saúde. Métodos Foi desenvolvido um modelo de Markov, no qual a medida de resultado de efetividade foi a razão custo-efetividade incremental (razão de custo-efetividade incremental: R$/ano de vida ajustado pela qualidade). Os custos médicos diretos foram obtidos por meio da perspectiva do Sistema Único de Saúde. O caso base foi composto de uma coorte hipotética de pacientes com glaucoma de ângulo aberto em uso de medicação tópica tratados de acordo com o Protocolo Clínico e Diretrizes Terapêuticas e um cenário do mundo real baseado em dados do Departamento de Informática do Sistema Único de Saúde. Foi testada a robustez do modelo por meio de análises de sensibilidade. Resultados No cenário base do Protocolo Clínico e Diretrizes Terapêuticas, o implante trabecular micro-bypass proporcionou ganhos de 0,47 ano de vida ajustado pela qualidade e razão de custo-efetividade incremental de R$7.996,66/ano de vida ajustado pela qualidade em relação ao tratamento com medicação tópica. No cenário real baseado em dados do Departamento de Informática do Sistema Único de Saúde, o implante trabecular proporcionou ganhos de 0,47 ano de vida ajustado pela qualidade e razão de custo-efetividade incremental de R$ 4.485,68/ano de vida ajustado pela qualidade em relação ao tratamento com medicação tópica. Os resultados foram robustos para análises de sensibilidade. Conclusão A incorporação do iStent inject® ao Sistema Único de Saúde proporciona melhora na qualidade de vida do paciente com um custo adicional que garante o benefício proporcionado a eles. Os resultados podem ser considerados custo-efetivos em comparação com a medicação tópica.


Subject(s)
Humans , Male , Female , Middle Aged , Unified Health System , Stents/economics , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/economics , Cost-Benefit Analysis , Costs and Cost Analysis , Trabeculectomy/economics , Visual Fields/physiology , Markov Chains , Health Care Costs , Quality-Adjusted Life Years , Health Resources/economics , Health Resources/statistics & numerical data , Intraocular Pressure/physiology
6.
Rev. habanera cienc. méd ; 20(4): e3810, 2021. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1289619

ABSTRACT

Introducción: la extracción del cristalino transparente en pacientes con cierre angular primario se plantea si existe presión intraocular mayor o igual que 30 mm Hg o daño por glaucoma. En ojos con elevación moderada de la presión intraocular se desconocen los resultados. Objetivo: evaluar la influencia de la presión intraocular preoperatoria en el control del cierre angular primario tratado con extracción del cristalino transparente. Material y Métodos: se realizó un estudio pre-experimental, entre enero de 2013 y enero de 2020, incluyó 78 ojos de 78 pacientes con cierre angular primario tratados con extracción del cristalino transparente; divididos en dos grupos según presión intraocular preoperatoria. Para el análisis estadístico se empleó chi cuadrado de independencia, probabilidad exacta de Fisher, prueba t para muestras independientes y análisis de varianza de medidas repetidas; con significación estadística del 95 por ciento. Resultados: hubo diferencias significativas entre ambos grupos para longitud axial (p=0,003), grosor del cristalino (p<0,001) y espesor corneal central (p=0,016). La presión intraocular y número de colirios, variaron de forma muy significativa (p<0,001) entre el pre y posoperatorio, y entre ambos grupos en los diferentes momentos analizados. En el grupo A el 94,4 por ciento de los ojos mostró control absoluto posoperatorio invariable en el tiempo, en el grupo B la mayoría de los ojos tuvo control relativo con diferencias muy significativas (p<0,001) entre ambos. Conclusiones: la presión intraocular preoperatoria influye en el control del cierre angular primario tratado con extracción del cristalino transparente; valores previos menores que 30 mm Hg, propician mejor control posoperatorio(AU)


Introduction: Clear lens extraction is considered in patients older than 50 years with primary angle closure and intraocular pressure greater than or equal to 30 mm Hg or damage due to glaucoma. The results are unknown in eyes with a moderate elevation of intraocular pressure. Objective: To evaluate the influence of preoperative intraocular pressure in the control of the primary angle closure treated with clear lens extraction. Material and Methods: A pre-experimental study was conducted between January 2013 and January 2020. It included a total of 78 eyes of 78 patients with primary angle closure treated with clear lens extraction. They were divided into two groups according to preoperative intraocular pressure. For statistical analysis, Chi-square test, Fisher's exact probability test, and t test were used for independent samples and analysis of variance with repeated measurements; with 95 percent statistical significance. Results: There were significant differences in axial length (p=0,003), lens thickness (p<0,001) and central corneal thickness (p=0,016) between both groups. Intraocular pressure and the number of eye drops varied very significantly (p<0,001) between the pre-and postoperative periods and between both groups at the different moments analyzed. In group A, 94,4 percent of the eyes showed absolute postoperative control, which remained unchanged over time. In group B, most eyes had relative control. There were very significant differences (p<0,001) between both groups. Conclusions: Preoperative intraocular pressure influences the control of primary angle closure treated with clear lens extraction; previous values less than 30 mm Hg favor better postoperative control(AU)


Subject(s)
Humans , Male , Female , Glaucoma/prevention & control , Intraocular Pressure , Intraocular Pressure/physiology , Lens, Crystalline , Postoperative Period
7.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 42(3): 309-313, May-June 2020. tab
Article in English | LILACS | ID: biblio-1132084

ABSTRACT

Objective: To compare intraocular pressure (IOP) and macular, retinal nerve fiber layer (RNFL), and ganglion cell layer (GCL) thicknesses in treatment-naive children with attention-deficit/hyperactivity disorder (ADHD), children with ADHD on regular methylphenidate (MPH) treatment for at least 3 months, and healthy controls. Methods: A total of 58 treatment-naive children with ADHD, 45 children with ADHD on regular MPH treatment, and 44 healthy controls were enrolled in this study. All participants underwent a comprehensive eye examination. Optical coherence tomography (OCT) was used to assess global RNFL thickness, central macular thickness, and GCL thickness in both eyes. Results: Separate univariate analysis of covariance (ANCOVA) on the outcome variables revealed a significant difference among the research groups with respect to IOP in the left eye. Post-hoc univariate analyses indicated that left IOP was significantly higher in children with ADHD under MPH treatment than among healthy controls. However, global RNFL thickness, central macular thickness, and GCL thickness of both eyes, as well as IOP in the right eye, were not significantly different across groups. Conclusion: Further longitudinal follow-up studies are needed to determine whether MPH treatment has any effect on IOP or OCT findings.


Subject(s)
Humans , Male , Female , Child , Adolescent , Retinal Ganglion Cells/pathology , Attention Deficit Disorder with Hyperactivity/physiopathology , Attention Deficit Disorder with Hyperactivity/pathology , Intraocular Pressure/physiology , Macula Lutea/pathology , Nerve Fibers/pathology , Reference Values , Retina/pathology , Case-Control Studies , Analysis of Variance , Tomography, Optical Coherence
8.
Rev. bras. oftalmol ; 78(6): 364-369, nov.-dez. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057914

ABSTRACT

Abstract Objective: The EX-PRESS device is a surgical alternative for the treatment of POAG. To describe the IOP behavior before and after the implantation of the EX-PRESS, the pharmacological treatment used in the pre and postoperative period and the complications in the first year of the postoperative period. Methods: A quantitative descriptive study with review of electronic medical records of a private ophthalmological reference hospital in Goiânia (GO) from 2013 to 2018. Sample composed of 8 eyes with POAG subjected to the EX-PRESS implant. We observed the variables: gender, age, operated eye, antiglaucomatous medications used, pre and postoperative intraocular pressure, and possible complications. Results: In the preoperative period, all eyes used antiglaucomatous drops, 75% used 3 or more different classes simultaneously. After 12 months of EX-PRESS, only 12.5% used three or more eye drops and 37.5% did not use any eye drops. On average, IOP varied from 18.63mmHg (SD 9.38) in the preoperative period to 14.50mmHg (SD 4.14) at 12 months postoperatively. Complications were: ocular hypotension, ocular hypertension; thinning of the conjunctival blister, cystic blister obstruction of the EX-PRESS. We resolved all coplications. Conclusion: The efficacy of EX-PRESS in IOP reduction was verified in the study. Concomitantly, there was a considerable decrease in anti-glaucomatous medications, and few associated complications.


Resumo Objetivo: O dispositivo EX-PRESS é uma alternativa cirúrgica para o tratamento do GPAA. Descrever o comportamento da PIO antes e após a implantação do EX-PRESS, o tratamento farmacológico utilizado no período pré e pós-operatório e as complicações no primeiro ano do pós-operatório. Métodos: Estudo descritivo quantitativo com revisão de prontuários eletrônicos de um hospital particular de referência oftalmológica de Goiânia (GO) no período de 2013 a 2018. Amostra composta por 8 olhos com GPAA submetidos ao implante de EX-PRESS. Foram observadas variáveis: sexo, idade, olho operado, medicações antiglaucomatosas usadas, pressão intraocular pré e pós-operatória, e possíveis complicações. Resultados: No pré-operatório, todos os olhos usavam colírios antiglaucomatosos, 75% faziam uso simultâneo de 3 ou mais classes diferentes. Após 12 meses do EX-PRESS, apenas 12,5% usavam três ou mais colírios e 37,5% não usavam nenhum colírio. Em média, as PIO variaram de 18,63 (DP 9,38) mmHg no pré-operatório para 14,50 (DP 4,14) mmHg em 12 meses do pós-operatório. As complicações foram: hipotensão ocular, hipertensão ocular,afinamento de bolha conjuntival, bolha cística, obstrução parcial do EX-PRESS. Conclusão: A eficácia do EX-PRESS na redução da PIO foi verificada na amostra desse estudo. Concomitantemente, constatou-se diminuição considerável de medicações anti-glaucomatosas, e poucas complicações associadas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Glaucoma, Open-Angle/surgery , Glaucoma Drainage Implants , Intraocular Pressure/physiology , Tonometry, Ocular/instrumentation , Electronic Health Records
9.
Rev. bras. oftalmol ; 78(3): 162-165, May-June 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1013675

ABSTRACT

RESUMO Objetivo: Comparar o resultado entre dois tipos de tonômetros, tendo como padrão ouro a tonometria de aplanação, relacionando com a espessura corneana e suas validações como instrumentos de rastreio populacional. Métodos: Estudo transversal comparativo, realizado com 400 olhos do ambulatório de oftalmologia da Adachi Oftalmologia, em Macapá (Amapá), entre os valores médios da pressão ocular medidos pelo tonômetro Icare®, o Tonômetro Pneumático e o Tonômetro de Aplanação de Goldmann em função da espessura corneana. Foram divididos conforme a ECC em 3 grupos. Grupo 1: 260 olhos com ECC< 530µ; grupo 2: 217 olhos com ECC entre 530µ e 590µ; e, grupo 3: 157 olhos com ECC>590µ. Resultados: A ECC média obtida na paquimetria foi de 557µ, variando de 651µ a 477µ (desvio padrão de 32.9). A PIO média obtida pela TP foi de 19,4 mmHg (com desvio padrão de 2,32); pelo Icare® foi de 16,7mmHg (desvio padrão de 2,12); e, na TAG foi de 15.5 mmHg (desvio padrão de 2,02). Para paquimetrias inferiores a 530µ e superiores a 590µ a PIOm não diferiu significativamente entre a TAG e Icare® (p = 0,232), sendo estatisticamente significativa diferença obtida para córneas com ECC entre 530 e 590 µ. A PIOm obtida pelo TP foi significativamente maior do que a pressão ocular média dos TAG e Icare® (p < 0,001 para ambos) em todos os grupos. Conclusões: Os três métodos podem ser utilizados em campanhas de rastreamento, porém o Icare® se mostrou mais confiável que a TP, com valores obtidos estatisticamente mais confiáveis quando comparados à TP. Existe suficiente concordância entre o Icare e a TAG para recomendar o seu uso.


ABSTRACT Objective: To compare the result between two types of tonometres, using as gold standard the aplanation tonometry, relating to the corneal thickness and its validations as instruments of population screening. Methods: A comparative cross-sectional study was carried out with 400 eyes from the ophthalmology clinic of Adachi Ophthalmology, in Macapá (Amapá), between the mean values of ocular pressure measured by the Icare® tonometro, the Pneumatic Tonometer and the Goldmann Flattening Tonometro as a function of corneal thickness. They were divided according to ECC in 3 groups. Group 1: 260 eyes with ECC <530µ; group 2: 217 eyes with ECC between 530µ and 590µ; and, group 3: 157 eyes with ECC> 590µ. Results: The mean ECC obtained in pachymetry was 557µ, ranging from 651µ to 477µ (standard deviation of 32.9). The mean IOP obtained by PT was 19.4 mmHg (with a standard deviation of 2.32); by Icare® was 16.7mmHg (standard deviation of 2.12); and in the TAG it was 15.5 mmHg (standard deviation of 2.02). For pachymetry less than 530µ and greater than 590µ, PIOm did not differ significantly between TAG and Icare® (p = 0.232), and a statistically significant difference was obtained for corneas with ECC between 530 and 590 µ. The IOP obtained by the PT was significantly higher than the mean ocular pressure of the TAG and Icare® (p <0.001 for both) in all groups. Conclusions: All three methods can be used in screening campaigns, but Icare® proved to be more reliable than TP, with values obtained statistically more reliable when compared to TP. There is sufficient agreement between Icare and TAG to recommend its use.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/diagnosis , Ocular Hypertension/diagnosis , Intraocular Pressure/physiology , Glaucoma/physiopathology , Cross-Sectional Studies , Air , Equipment Design , Corneal Pachymetry
10.
Arq. bras. oftalmol ; 82(3): 200-206, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001295

ABSTRACT

ABSTRACT Purpose: Obesity is accepted as a risk factor for postoperative visual loss due to possible perioperative elevations in intraocular pressure. This study investigated whether intraocular pressure changes differed according to the body mass index of patients undergoing laparoscopic cholecystectomy. Methods: Thirty obese and 30 non-obese patients (body mass index cutoff point, 30 kg/m2) undergoing laparoscopic cholecystectomy were enrolled. Intraocular pressure was measured at baseline (T1), after induction of anesthesia (T2), 5 min after initiation of mechanical ventilation (T3), 5 min after pneumoperitoneum inflation (T4), 5 min after the patient was placed in the head-up position (T5), 5 min after deflation with the patient in the supine position (T6), and 5 min after extubation with the patient in the 30 degrees upright position (T7). Results: The mean intraocular pressure values of the obese and non-obese groups were similar at T1 (16.60 ± 2.93 and 16.87 ± 2.85 mmHg respectively). In both groups, intraocular pressure decreased following initiation of anesthesia (T2) (p<0.001, T2 vs T1). Intraocular pressure values at T7 were significantly higher than those at T1 in the obese (20.38 ± 4.11 mmHg, p<0.001) and non-obese (20.93 ± 4.37 mmHg, p<0.01) groups. There were no significant differences between intraocular pressure values of obese and non-obese patients at any time point. Conclusions: Obesity is not correlated with intraocular pressure during short laparoscopic surgeries with the patient in the head-up position.


RESUMO Objetivo: A obesidade é aceita como um fator de risco para a perda visual pós-operatória devido a possíveis elevações perioperatórias da pressão intraocular. Este estudo investigou se as alterações na pressão intraocular diferem de acordo com o índice de massa corporal dos pacientes submetidos à colecistectomia laparoscópica. Métodos: Trinta pacientes obesos e 30 não-obesos (limiar de índice de massa corporal de 30 kg/m2), submetidos à colecistectomia laparoscópica foram incluídos. A pressão intraocular foi medida no início do estudo (T1), após a indução anestésica (T2), 5 min após o início da ventilação mecânica (T3), 5 min após a insuflação do pneumoperitôneo (T4), 5 min após o posicionamento vertical da cabeça (T5), 5 min após a deflação na posição em decúbito dorsal (T6) e 5 min após a extubação com o paciente na posição vertical de 30 graus (T7). Resultados: Os valores médios da pressão intraocular dos grupos obeso e não obeso foram semelhantes no T1 (16,60 ± 2,93 e 16,87 ± 2,85 mmHg, respectivamente). Em ambos os grupos, a pressão intraocular diminuiu após o início da anestesia (T2) (p<0,001, T2 vs T1). Os valores da pressão intraocular em T7 foram significativamente maiores do que aqueles em T1 nos grupos obesos (20,38 ± 4,11 mmHg, p<0,001) e não obesos (20,93 ± 4,37 mmHg, p<0,01). Não houve diferenças significativas entre os valores de pressão intraocular de pacientes obesos e não obesos em qualquer momento. Conclusões: A obesidade não está correlacionada com a pressão intraocular durante cirurgias laparoscópicas curtas com o paciente em posição de cabeça erguida.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Young Adult , Cholecystectomy, Laparoscopic/adverse effects , Intraocular Pressure/physiology , Obesity/complications , Obesity/physiopathology , Reference Values , Time Factors , Tonometry, Ocular/methods , Body Mass Index , Ocular Hypertension/etiology , Ocular Hypertension/physiopathology , Analysis of Variance , Supine Position/physiology , Statistics, Nonparametric , Patient Positioning
11.
Arq. bras. oftalmol ; 82(3): 220-224, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001299

ABSTRACT

ABSTRACT Purpose: Beta-thalassemia minor, a common hereditary blood disorder in Mediterranean countries such as Turkey, is associated with insulin resistance. Insulin resistance, in turn, can be associated with excessively high intraocular pressure and, therefore, intraocular pressure-induced blindness. This study aimed to investigate the intraocular pressure in subjects with beta-thalassemia minor. Methods: We conducted a cross-sectional study comprising of 203 subjects divided into two groups: beta-thalassemia minor (103) and healthy (100).Hemoglobin electrophoresis was performed and complete blood count, blood pressures, serum fasting glucose and insulin levels were measured. All subjects underwent ophthalmological examinations including intraocular pressure measurements. Results: Intraocular pressure in the subjects with beta-thalassemia minor was significantly lower than that in healthy subjects (p=0.007). Additionally, intraocular pressure was inversely correlated with hemoglobin A2 levels (p=0.001, r=-0.320). Serum insulin and systolic blood pressure were significantly higher in subjects with beta-thalassemia minor (p=0.03, p=0.009, respectively). Conclusion: Subjects with beta-thalassemia minor had lower intraocular pressure than healthy controls, suggesting beta-thalassemia minor may actually protect against high intraocular pressure.


RESUMO Objetivo: Beta-talassemia menor é uma doença hereditária comum no sangue em países mediterrâneos como a Turquia e está associada à resistência à insulina. A resistência à insulina por sua vez, pode estar associada à pressão intraocular excessivamente alta e, portanto à cegueira induzida pela pressão intraocular. Este estudo teve como objetivo investigar a pressão intraocular em indivíduos com beta-talassemia menor. Métodos: Foi realizado um estudo transversal compreendendo 203 indivíduos divididos em 2 grupos: beta-talassemia menor (103) e saudável (100). Eletroforese de hemoglobina foi realizada e hemograma completo, pressão arterial, glicemia em jejum e níveis de insulina medidos. Todos os indivíduos foram submetidos foram submetidos a exames oftalmológicos, incluindo medidas de pressão intraocular. Resultados: A pressão intraocular nos indivíduos com beta-talassemia menor foi significativamente menor do que em indivíduos saudáveis (p=0,007). Além disso, a pressão intraocular foi inversamente correlacionada com os níveis de hemoglobina A2 (p=0,001, r=-0,320). Insulina sérica e pressão arterial sistólica foram significativamente maiores em indivíduos com beta-talassemia menor (p=0,03, p=0,009, respectivamente). Conclusão: Os indivíduos com beta-talassemia menor tiveram pressão intraocular menor do que os controles saudáveis, sugerindo que a beta-talassemia menor pode, na verdade, proteger contra a alta pressão intraocular.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , beta-Thalassemia/physiopathology , Intraocular Pressure/physiology , Reference Values , Tonometry, Ocular , Triglycerides/blood , Blood Glucose/analysis , Blood Pressure/physiology , Hemoglobin A2/analysis , Insulin Resistance/physiology , Case-Control Studies , Linear Models , Cross-Sectional Studies , beta-Thalassemia/blood , Statistics, Nonparametric , Insulin/blood , Lipoproteins, HDL/blood , Lipoproteins, LDL/blood
12.
Arq. bras. oftalmol ; 82(3): 176-182, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001308

ABSTRACT

ABSTRACT Purpose: To correlate provocative test-based intraocular pressure (IOP) variation parameters (fluctuation and peak) with functional status, and to compare these IOP parameters between treated eyes with asymmetric primary open-angle glaucoma (POAG). Methods: A prospective observational study including consecutively treated patients with primary open-angle glaucoma was performed. Subjects with ocular diseases other than glaucoma or previous incisional glaucoma surgery were excluded. The primary inclusion criteria were 33 visual field tests and 32 years of follow-up, without any changes on current medical regimen. Long-term intraocular pressure parameters were acquired via isolated intraocular pressure measurements from the patients' last 5 office visits. To evaluate provocative test-based intraocular pressure parameters, all patients were submitted to a water drinking test. Initially, the partial correlation coefficients between each intraocular pressure variation parameter and visual field mean deviation were calculated, adjusting for the baseline intraocular pressure and number of antiglaucoma medications. In addition, each intraocular pressure parameter was compared between eyes with better visual field mean deviation and fellow eyes with worse visual field mean deviation in patients with asymmetric visual field loss (defined as an inter-eye visual field mean deviation difference of at least 3 dB). Results: A total of 87 eyes (87 patients; mean age, 61.9 ± 12.5 years; 59.8% women) with primary open-angle glaucoma were included. The patients underwent a median of 5 visual field tests, with a mean follow-up of 4.3 ± 1.4 years. Neither long-term nor water-drinking test intraocular pressure variation parameters were significantly associated with visual field mean deviation values (p30.117). In the subgroup with asymmetric visual field loss (64 eyes of 32 patients; mean age, 65.0 ± 11.4 years), neither long-term water-drinking test intraocular pressure variation parameters differed significantly between eyes with better and worse visual field mean deviation (p30.400). Conclusion: Our results indicate that neither long-term intraocular pressure variation parameters nor stress test-derived intraocular pressure metrics, as assessed by the water-drinking test, appear to correlate with the visual field status or differ significantly between eyes with asymmetric visual field damage, suggesting that other factors may explain such functional asymmetry, and that the water-drinking test does not add significant information to these cases.


RESUMO Objetivo: Correlacionar os parâmetros de variação da pressão intraocular (flutuação e pico) com o dano funcional em pacientes tratados com glaucoma primário de ângulo aberto, e comparar esses parâmetros de pressão intraocular entre olhos com dano funcional assimétrico. Métodos: Estudo observacio nal prospectivo foi realizado incluindo consecutivamente pa cientes tratados com glaucoma primário de ângulo aberto. Foram excluídos indivíduos com outras doenças oculares que não o glaucoma ou cirurgia prévia incisional de glaucoma. Os principais critérios de inclusão foram: 33 testes de campo visual e 32 anos de acompanhamento, sem quaisquer alterações no regime medicamentoso atual. Parâmetros de pressão intraocular de longo prazo foram obtidos através de medidas de pressão intraocular isoladas de cada consulta (as últimas 5 consultas de cada paciente foram consideradas para análise). Para avaliação dos parâmetros de pressão intraocular de curto prazo, todos os pacientes foram submetidos ao teste de sobrecarga hídrica. Ini cialmente, calculamos os coeficientes de correlação parcial de cada parâmetro de variação da pressão intraocular com o nível de dano funcional, baseado no índice Mean Deviation (MD), ajustando para a pressão intraocular basal e o número de medicações antiglaucomatosas. Além disso, comparamos cada parâmetro de pressão intraocular entre os olhos com melhor e pior nível de dano funcional em pacientes com perda de campo visual assimétrica (definida como diferença no índice mean deviation entre os olhos de pelo menos 3 dB). Resultados: Foram incluídos 87 olhos (87 pacientes) com glaucoma primário de ângulo aberto. A idade média foi de 61,9 ± 12,5 anos e 59,8% eram mulheres. Em geral, os pacientes foram submetidos a 5 testes (mediana) de campo visual, com um seguimento médio de 4,3 ± 1,4 anos. Nem os parâmetros de variação da pressão intraocular de longo prazo nem aqueles obtidos pelo teste de sobrecarga hídrica se correlacionaram significativamente com o nível de dano no campo visual (p30,117). No subgrupo com perda de campo visual assimétrica (64 olhos de 32 pacientes; idade média, 65,0 ± 11,4 anos), nem os parâmetros de variação da pressão intraocular de longo prazo nem os obtidos pelo teste de sobrecarga hídrica diferiram significativamente entre olhos com melhor e pior nível de dano funcional (p3 0,400). Conclusão: Nossos resultados indicam que não apenas parâmetros de variação da pressão intraocular de longo prazo, mas também medidas de pressão intraocular derivadas do teste de sobrecarga hídrica, não parecem se correlacionar com o nível de dano do campo visual, nem diferem significativamente entre olhos com nível de dano funcional assimétrico. Esses achados sugerem que outros fatores poderiam explicar essa assimetria funcional e que o teste de sobrecarga hídrica não acrescenta informações significativas a esses casos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Glaucoma, Open-Angle/physiopathology , Intraocular Pressure/physiology , Reference Values , Time Factors , Tonometry, Ocular , Water/physiology , Visual Fields/physiology , Glaucoma, Open-Angle/therapy , Prospective Studies , Statistics, Nonparametric , Visual Field Tests
13.
Rev. bras. oftalmol ; 78(2): 122-126, mar.-abr. 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1003567

ABSTRACT

Resumo Objetivos: Correlacionar parâmetros oftalmoscópicos e cardiovasculares em pacientes com diagnóstico de insuficiência cardíaca com fração de ejeção reduzida (ICFER) e avaliar a associação entre ICFER e alterações do nervo óptico sugestivas de glaucoma. Métodos: Estudo descritivo, observacional, prospectivo, composto por amostra 30 pacientes com diagnóstico de ICFER. Os pacientes foram submetidos ao exame oftalmológico, que incluiu biomicroscopia, avaliação da acuidade visual, aferição da PIO (pressão intraocular), gonioscopia e medida de ECC (espessura central corneana). A avaliação de parâmetros cardiovasculares, como PAM (pressão arterial média), FEVE (fração de ejeção do ventrículo esquerdo), comorbidades e tempo de diagnóstico de IC foi realizada a partir de revisão de prontuário médico. Arbitrariamente foi escolhido o olho esquerdo para análise estatística dos dados. A correlação estatística foi realizada através do teste de Spearman, e a comparação através do teste U de Mann-Whitney. Resultados: Observou-se uma alta prevalência de atrofia peripapilar (73,3%), além de uma correlação positiva, moderada e estatisticamente significativa entre FEVE e PPO (pressão de perfusão ocular) (r = 0,517; p = 0,004). Apesar da ausência de significância das comparações pelo Teste U de Mann-Whitney, evidenciou-se uma maior prevalência de atrofia peripapilar nos pacientes que apresentavam uma menor PAM, menor FEVE e menor PPO. Conclusão: A ICFER pode ser um fator de risco para o desenvolvimento de alterações glaucomatosas no disco do nervo óptico. A atrofia peripapilar e a baixa pressão de perfusão ocular resultantes do déficit contrátil cardíaco podem estar relacionadas com a teoria vascular do desenvolvimento do glaucoma de pressão.


Abstract Objectives: To correlate ophthalmoscopic and cardiovascular parameters in patients diagnosed with low-output heart failure (HFrEF) and to evaluate the association between HFrEF and glaucoma-suggestive alterations in the optic nerve. Methods: Descriptive, observational and prospective study, composed of 30 patients diagnosed with HFrEF. The patients were submitted to ophthalmologic examination, which included biomicroscopy, visual acuity, gonioscopy, intraocular pressure (IOP) and central corneal thickness (CCT) measurement. Their cardiovascular parameters evaluation, such as mean arterial pressure (MAP), left ventricular ejection fraction (LVEF), comorbidities and diagnosis time of HFrEF was performed upon a review over their medical chart. The left eye was arbitrarily chosen for statistical analysis of the data. Statistical correlation was performed using the Spearman test, while the comparison was performed using the Mann-Whitney U-test. Results: A high prevalence of peripapillary atrophy (73.3%) was observed, as well as a positive, moderate and statistically significant correlation between LVEF and ocular perfusion pressure (OPP) (r = 0.517; p = 0.004). Despite the lack of significance of the Mann-Whitney U-Test comparisons, a higher prevalence of peripapillary atrophy was found in patients with lower MAP, lower LVEF and lower OPP. Conclusion: HFrEF may be a risk factor for the development of glaucomatous changes in the optic nerve disc. The resulting peripapillary atrophy and low OPP from the contractile deficit may be related to the vascular theory about normal-tension glaucoma development.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Glaucoma, Open-Angle/etiology , Heart Failure/complications , Optic Nerve , Stroke Volume , Optic Nerve Diseases , Glaucoma, Open-Angle/diagnosis , Epidemiology, Descriptive , Prospective Studies , Risk Factors , Diagnostic Techniques, Ophthalmological , Arterial Pressure , Observational Study , Intraocular Pressure/physiology
15.
Rev. cuba. oftalmol ; 32(1): e703, ene.-mar. 2019. tab
Article in Spanish | LILACS | ID: biblio-1093669

ABSTRACT

RESUMEN Objetivo: Evaluar el comportamiento de la presión intraocular posterior a la cirugía de catarata por facoemulsificación en el Instituto Cubano de Oftalmología Ramón Pando Ferrer. Métodos: Se realizó un estudio descriptivo y prospectivo de serie de casos en pacientes atendidos en el Servicio de Microcirugía Ocular en el Instituto Cubano de Oftalmología Ramón Pando Ferrer en dos años. La muestra estuvo conformada por 63 ojos operados por un mismo cirujano y que cumplieron los criterios de inclusión y exclusión. Las variables del estudio fueron presión intraocular preoperatoria y posoperatoria, mejor agudeza visual con corrección y sin ella, antecedentes patológicos personales y oculares de glaucoma, sexo, dureza del cristalino según LOCS III, equivalente esférico esperado y obtenido y astigmatismo medio inducido por la cirugía. Resultados: En el estudio predominaron los pacientes del sexo femenino, sin antecedente de glaucoma ni de hipertensión arterial, con dureza del cristalino III y IV. La presión intraocular media más elevada se observó a las 24 horas posterior a la cirugía (p= 0,002), para los grupos de dureza del cristalino ll, lll y lV, la cual disminuyó en los pacientes con antecedentes de glaucoma desde el posoperatorio inmediato. No se encontró relación entre la variación de la presión intraocular media y el antecedente de hipertensión arterial. La mejor agudeza visual corregida posoperatoria mejoró significativamente (p= 0,000). El componente esférico obtenido no presentó diferencias significativas respecto al esperado. La diferencia de la media del cilindro preoperatorio y posoperatorio fue significativa (p= 0,000). Conclusión: La facoemulsificación reduce de modo efectivo la presión intraocular en sujetos glaucomatosos y no glaucomatosos(AU)


ABSTRACT Objective: Evaluate the behavior of intraocular pressure after phacoemulsification cataract surgery. Methods: A prospective descriptive case-series study was conducted of patients attending the Ocular Microsurgery Service of Ramón Pando Ferrer Cuban Institute of Ophthalmology in a period of two years. The sample was 63 eyes operated on by the same surgeon and meeting the inclusion and exclusion criteria. The study variables were pre- and postoperative intraocular pressure, best visual acuity with and without correction, personal pathological antecedents, a history of ocular glaucoma, sex, crystalline lens hardness by LOCS III, expected and obtained spherical equivalent, and surgery-induced medial astigmatism. Results: A predominance was found of female patients without a history of glaucoma or hypertension and a crystalline lens hardness of III and IV. The highest mean intraocular pressure was observed 24 hours after surgery (p= 0.002) in crystalline hardness groups II, III and IV. Mean intraocular pressure decreased in patients with glaucoma antecedents as of the immediate postoperative period. No relationship was found between mean intraocular pressure variation and hypertension antecedents. The best corrected postoperative visual acuity improved significantly (p= 0.000). No significant differences were observed between the expected and the obtained spherical component. The difference between the mean pre- and post-operative cylinder was significant (p= 0.000). Conclusion: Phacoemulsification effectively reduces intraocular pressure in glaucoma and non-glaucoma patients(AU)


Subject(s)
Humans , Male , Female , Cataract Extraction/methods , Phacoemulsification/adverse effects , Intraocular Pressure/physiology , Epidemiology, Descriptive , Prospective Studies
16.
Arq. bras. med. vet. zootec. (Online) ; 71(1): 177-186, jan.-fev. 2019. tab, graf
Article in Portuguese | LILACS, VETINDEX | ID: biblio-989369

ABSTRACT

No presente estudo, foram avaliados parâmetros oftalmológicos de 38 bovinos das raças Nelore (n= 19; grupo GN) e Gir (n= 19; grupo GG), machos, com idade média de 15 meses. Os exames oftalmológicos realizados foram teste lacrimal de Schirmer 1 (TLS-1), tonometria de aplanação, retinografia e biometria por ultrassonografia em modo B. Os resultados do TLS-1, tonometria de aplanação e biometria ocular foram avaliados por meio da análise de variância (ANOVA), e as médias comparadas pelo teste de Tukey. Para o exame de retinografia, foi realizada a análise descritiva das estruturas anatômicas. O TLS-1 e a tonometria não diferiram (P≥0,05) nas comparações entre os olhos e entre os grupos raciais. A retinografia permitiu a visualização do disco óptico, dos vasos retinianos, do fundo tapetal e não tapetal, sem constatação de diferenças anatômicas entre as raças. Por meio da biometria ocular, foram observados valores maiores nos animais da raça Gir para as medidas do comprimento axial (CAx), da espessura da lente (EL) e da profundidade da câmara vítrea (CV), em ambos os eixos, horizontal (CAH) e vertical (CAV). Os exames oftalmológicos realizados podem ser executados a campo sem comprometer o bem-estar dos animais. Somente na ultrassonografia em modo B foram identificadas diferenças entre os bovinos das raças Nelore e Gir.(AU)


The ophthalmological parameters were evaluated of 38 male Nelore bovine (n= 19, GN group) and Gir (n= 19, GG group), with 15 months age. The ophthalmological examinations by Schirmer 1 (TLS-1), aplanation tonometry, retinography and B-mode ultrasonography were done. The results of the TLS-1, aplanation tonometry and ocular biometry were evaluated by analysis of variance and means compared by the Tukey test. A descriptive analysis of the anatomical structures was performed for the retinography examination. TLS-1 and tonometry did not differ (P≥ 0.05) in the comparisons between the eyes and between the groups. Retinography allowed the visualization of the optic disc, retinal vessels, tapetal and non-tapetal fundus, without any anatomical differences between the breed. In the ocular biometry, higher values were observed in Gir animals for measurements of axial length (CAx), lens thickness (EL) and depth of the vitreous chamber (CV), both horizontal (CAH) and vertical (CAV) imaging planes. Ophthalmologic examinations can be performed on the field without compromising animal welfare. Differences between Nelore and Gir bovines were identified only by B-mode ultrasonography.(AU)


Subject(s)
Animals , Cattle , Cattle/physiology , Lacrimal Elimination , Intraocular Pressure/physiology , Biometry
18.
Rev. bras. oftalmol ; 77(6): 311-315, nov.-dez. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-985316

ABSTRACT

Resumo Objetivo: Avaliar a variação da pressão intraocular e da pressão de perfusão ocular durante sessão de hemodiálise, nos períodos pré, intra (a cada hora) e pós dialítico, em pacientes tratados em Serviços de Referência em hemodiálise da cidade de Fortaleza - CE. Métodos: O estudo foi longitudinal e prospectivo. 45 pacientes foram submetidos à hemodiálise. Todos os pacientes foram recrutados a fazer um exame oftalmológico, além da aferição da pressão intraocular com o Tonopen. Resultados: A amostra foi composta por 26 homens e 19 mulheres com idade média de 51,8 anos. O estudo revelou que há uma diferença importante entre a pressão intraocular pré e pós hemodiálise, diminuindo em média 2,59 mmHg. Ao analisar a pressão de perfusão ocular, foi encontrado um aumento médio de 1,85 mmHg entre o início e o término da hemodiálise. Conclusão: De acordo com o presente estudo, o processo de hemodiálise é um procedimento aparentemente seguro em relação à alteração da pressão intraocular e da pressão de perfusão ocular, como causadores de patologias oculares, principalmente o glaucoma.


Abstract Objective: To evaluate the variation of intraocular pressure and ocular perfusion pressure during hemodialysis sessions, in the pre, intra (hourly) and post dialytic periods, in patients treated at Hemodialysis Reference Services in Fortaleza - CE. Methods: The study was longitudinal and prospective. 45 patients underwent hemodialysis. All patients were recruited to undergo an ophthalmologic examination, in addition to the intraocular pressure measurement with Tonopen. Results: The sample consisted of 26 men and 19 women with a mean age of 51.8 years. The study revealed that there is an important difference between pre and post hemodialysis intraocular pressure, decreasing by an average of 2.59 mmHg. When analyzing ocular perfusion pressure, an average increase of 1.85 mmHg was found between the onset and end of hemodialysis. Conclusion: According to the present study, the hemodialysis process is an apparently safe procedure in relation to altered intraocular pressure and ocular perfusion pressure, as causes of ocular pathologies, mainly glaucoma.


Subject(s)
Humans , Male , Female , Middle Aged , Blood Pressure/physiology , Renal Dialysis , Eye/blood supply , Intraocular Pressure/physiology , Ophthalmoscopy , Regional Blood Flow , Time Factors , Tonometry, Ocular , Visual Acuity , Prospective Studies , Longitudinal Studies , Slit Lamp Microscopy
19.
Arq. bras. oftalmol ; 81(6): 461-465, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-973861

ABSTRACT

ABSTRACT Purpose: We aimed to evaluate choroidal per­fusion changes in obese patients using optical coherence tomography and dynamic contour tonometry, to determine whether these changes are associated with body mass index, and to assess the ocular effects of insulin resistance. Methods: We retrospectively evaluated the data of 32 obese patients with body mass index >30 kg/m2 and 45 healthy control individuals. Intraocular pressure and ocular pulse amplitude values of the patients were measured using dynamic contour tonometry, and the mean choroidal thickness was measured using enhanced depth imaging optical coherence tomography. Insulin resistance was assessed using the homeostasis model assessment-estimated insulin resistance index. Results: The mean choroidal thickness (294.30 ± 60.87 μm) and ocular pulse amplitude (2.10 ± 0.74) were lower, whereas the mean intraocular pressure (16.61 ± 2.35 mmHg) was higher in obese patients than in controls. There was a significant negative correlation between body mass index and ocular pulse amplitude (r=-0.274; p=0.029) and an insignificant negative correlation between mean choroidal thickness, intraocular pressure, and body mass index. There was an insignificant negative correlation between homeostasis model assessment-estimated insulin resistance index, mean choroidal thickness, and intraocular pressure and significant ne­gative correlation between homeostasis model assessment-estimated insulin resistance index and ocular pulse amplitude (r=-0.317; p=0.022). Conclusion: We found reduced mean choroidal thickness and ocular pulse amplitude and increased mean intraocular pressure in obese patients. These changes indicated a decrease in choroidal perfusion and ocular blood flow. It may be possible to detect ocular blood flow changes in obese patients through noninvasive assessment using the choroid. The negative correlation between insulin resistance and ocular pulse amplitude may be associated with intracellular fat accumulation in obese patients.


RESUMO Objetivo: Avaliar as alterações da perfusão coroidiana em pacientes obesos utilizando tomografia de coerência óptica e a tonometria de contorno dinâmico, para determinar se essas alterações estão associadas ao índice de massa corporal e avaliar os efeitos oculares da resistência à insulina. Métodos: Foram avaliados, retrospectivamente, os dados de 32 pacientes obesos, com índice de massa corporal >30 kg/m2, e 45 controles saudáveis. Os valores de pressão intraocular e da amplitude de pulso ocular dos pacientes foram medidos por meio de tonometria de contorno dinâmico e a espessura média da coroide foi medida por tomografia de coerência óptica com profundidade de imagem aprimorada. A resistência à insulina foi avaliada usando o índice de estimativa da resistência à insulina pelo modelo de homeostase. Resultados: A espessura média da coroideia (294,30 ± 60,87 μm) e a amplitude de pulso ocular (2,10 ± 0,74) foram menores, enquanto a pressão intraocular média (16,61 ± 2,35 mmHg) foi maior nos obesos do que nos controles. Houve uma correlação negativa significativa entre o índice de massa corporal e a amplitude de pulso ocular (r=-0,274; p=0,029) e uma correlação negativa insignificante entre a espessura média da coroide, a pressão intraocular e o índice de massa corporal. Houve uma correlação negativa insignificante entre a avaliação do modelo de homeostase - estimativa do índice de resistência à insulina, espessura média da coróide e pressão intraocular e correlação negativa significativa entre o modelo de avaliação de homeostase - o índice de resistência à insulina estimado e a amplitude de pulso ocular (r=-0,317; p=0,022). Conclusão: Encontramos redução da espessura média da coroide e da amplitude de pulso ocular e aumento da pressão intraocular em pacientes obesos. Essas alterações indicaram uma diminuição na perfusão coroidal e no fluxo sanguíneo ocular. Pode ser possível detectar alterações no fluxo sanguíneo ocular em pacientes obesos por meio de avaliação não invasiva usando a coróide. A correlação negativa entre a resistência à insulina e a amplitude de pulso ocular pode estar associada ao acúmulo de gordura intracelular em pacientes obesos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Insulin Resistance/physiology , Choroid/diagnostic imaging , Obesity/complications , Tonometry, Ocular , Pulsatile Flow/physiology , Body Mass Index , Retrospective Studies , Choroid/blood supply , Tomography, Optical Coherence , Intraocular Pressure/physiology
20.
Rev. bras. oftalmol ; 77(5): 235-239, set.-out. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-977872

ABSTRACT

Resumo Objetivo: Relatar perfil clínico epidemiológico de pacientes que apresentaram o pico hipertensivo após o IVA e apontar possíveis fatores de risco associados. Métodos: Estudo retrospectivo, observacional e descritivo (revisão de prontuário de pacientes assistidos no IBOPC) de 2014 a 2016. Resultados: Foram analisados 40 pacientes com glaucoma submetidos à implante de válvula de Ahmed. O diagnóstico pré-operatório mais comum foi glaucoma secundário, sendo a indicação pós-transplante penetrante de córnea a mais frequente. 95% das cirurgias foi de implante de tubo isolado. 56% dos pacientes tinham cirurgia anti- glaucomatosa prévia. 46% necessitaram de procedimento cirúrgico posterior para manejo de complicações pós-operatórias, sendo que a mais frequente foi atalamia (9,7%). PIO média no pré-operatório = 28,6 ± 12.20mmHg, com uso de 3,41 medicações. Com 3 semanas a PIO média aumentou para 16mmHg, com uso de 0,42 medicações. Após 3 meses de cirurgia a PIO média estava em 16.5mmHg, com uso de 1,86 de medicações. Após 6 meses de seguimento a PIO média reduziu (16,4 ± 6.74mmHg), com 2,23 ± 1.45 medicações. A média da AV (Snellen) foi de 20/100p no pré-operatório e de 20/200 após 6° mês de cirurgia. Catorze pacientes preencheram os critérios para a FH, destes 6 obtiveram resolução da FH. Dos pacientes que desenvolveram a FH, 78,4% iniciaram a elevação da PIO entre a 2ª e 4ª semana de pós-operatório. Seis (14,6%) pacientes obtiveram sucesso cirúrgico completo, parcial em 36,6% e falência 31%. Conclusão: A fase hipertensiva pode ocorrer em parte dos pacientes após as semanas iniciais do procedimento cirúrgico. O conhecimento deste fenômeno, o preparo prévio do cirurgião, o acompanhamento regular do paciente e o controle da PIO com o uso de medicações são determinantes na resolução desta complicação.


Abstract Objective: To report the clinical epidemiological profile of patients who presented the hypertensive peak after VAT and to indicate possible associated risk factors. Methods: A retrospective, observational and descriptive study (review of medical records of patients assisted in the IBOPC) from 2014 to 2016. Results: We analyzed 40 patients with glaucoma submitted to Ahmed Glaucoma Valve implant. The most common preoperative diagnosis was secondary glaucoma, with the most frequent corneal penetrating post-transplant indication. 95% of the surgeries were of isolated tube implantation. 56% of patients had previous anti-glaucomatous surgery. 46% needed a posterior surgical procedure to manage postoperative complications, and the most frequent was atalamia (9.7%). IOP preoperatively = 28.6 ± 12.20mmHg, with use of 3.41 medications. At 3 weeks the mean IOP increased to 16mmHg, with use of 0.42 medications. After 3 months of surgery the mean IOP was 16.5mmHg, with use of 1.86 of medications. After 6 months of follow-up the mean IOP decreased (16.4 ± 6.74 mmHg), with 2.23 ± 1.45 medications. The mean of the AV (Snellen) was 20 / 100p in the preoperative period and 20/200 after the 6th month of surgery. Fourteen patients fulfilled the criteria for HP, of which 6 obtained HP resolution. Of the patients who developed HP, 78.4% started to elevate IOP between the 2nd and 4th postoperative week. Six (14.6%) patients had complete surgical success, partial in 36.6% and bankruptcy in 31%. Conclusion: The hypertensive phase may occur in part of the patients after the initial weeks of the surgical procedure. The knowledge of this phenomenon, the previous preparation of the surgeon, the regular monitoring of the patient and the control of IOP with the use of medications are determinant in the resolution of this complication.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Glaucoma/surgery , Ocular Hypertension/etiology , Prosthesis Implantation/adverse effects , Glaucoma Drainage Implants , Intraocular Pressure/physiology , Postoperative Complications , Ocular Hypertension/physiopathology , Medical Records , Epidemiology, Descriptive , Retrospective Studies , Prosthesis Implantation/methods , Observational Study
SELECTION OF CITATIONS
SEARCH DETAIL